The most efficient compressed air measurement method – directly on site or directly in the EtherCAT system

Technical Communication Based on the experience of installing DPDT dynamic positioning dynamic track a trace system on three dredgers, the configuration of the power system is critical. In the initial design of the ship's plan, it is necessary to analyze the dynamic positioning capability according to the selected main propulsion CPP, rudder and bow thruster, and consider the marine environment and operation mode of the actual operation of dredging and digging S, and adjust the main propulsion CPP, rudder and stern side. The power of the pusher.

It is believed that the DPDT dynamic positioning dynamic trajectory system will be more maturely used on dredgers, and through its powerful computational analysis capabilities, accurate mathematical models, and reasonable power configuration, it can make the crew from heavy operations. Relieve in the process, improve the accuracy and efficiency of the operation, effectively shorten the construction time, reduce the cost, and improve the competitiveness of dredgers participating in international dredging competition.

Wang Fang: Wan Jia: Xu Yuru, etc. Dynamic positioning modeling and simulation of deepwater semi-submersible drilling platform. Marine Engineering, 2011, 33(3): 75-78. Compressed air is still used in almost all industry sectors, whether for driving, control, motion or transmission. For efficient machine processing, compressed air must be analyzed and monitored as thoroughly as possible and integrated into the control system in an optimal manner. The EtherCAT terminal box EP3744 is a compact, all-in-one solution for this application. This IP67-rated terminal box integrates compressed air measurement, EtherCAT connection and digital I/O, which can be used directly on the processing site and installed outside the electrical cabinet.

In addition to the 6 digital inputs and 2 digital outputs, the EtherCAT terminal means that the EP3744 has 4 pressure inputs and integrates 6mm ampere fittings. The pressure is measured as the difference from the fifth pressure connection and is connected via a hose to a protective enclosure with IP 67 protection. The measured value is provided in the form of a 16-bit value that is transmitted to the controller in an electrically isolated manner. The measuring range is "1 bar (15 psi) with a resolution of 1 mbar per digit. These allow this stand-alone compact stand-alone unit to be used for direct measurement and monitoring of field pressure. On the one hand, the need to remove from the machining site to the control cabinet The long route and hose connection. On the other hand, frequent provisioning of the specified electrical isolation and pneumatic system isolation becomes extremely simple. The other advantages of the system's integrated solution are also the short response time. Because of the local measurement, only one A/ is used. The D converter implements an EtherCAT interface and other digital I/Os, so it can be integrated into the control system particularly efficiently.

Detect and eliminate leaks to reduce energy consumption. In addition to control and regulation, analysis and diagnosis are also essential where pneumatic systems are used. For example, the operating pressure can be monitored using the EtherCAT terminal box EP3744, which increases the transparency of the device. Another important feature is to eliminate leaks, which can reduce the energy costs associated with generating compressed air. Distributed and system-integrated pressure measurement is also an ideal solution for detecting and determining leak locations.

The EP3744 also makes the process flow smoother: for example, the vacuum required for the clamping process in a fully automated pick-and-place machine can be monitored without difficulty. For this purpose, the EtherCAT terminal box can be integrated into the compressed air supply system of the gripper with a simple joint (T-joint).

Beckhoff always takes PC-based automation as its development concept. The industrial PC, fieldbus module, drive products and TwinCAT automation software form a complete and compatible control system for each industrial control field. Provide open automation systems and complete solutions.

For more than 30 years, Beckhoff's component and system solutions have been used worldwide.

RoHS UL Free samples pvc wire harness end cap

RoHS UL Free samples pvc wire harness end cap



large size steel pipe end cap, insulated pipe end cap (1)
Any  customized dimension & color would be welcome!
Application:                                                                                          
RoHS UL Free samples pvc wire harness end cap  is manufactured by the workmanship of Dip Molding to protect the end of cable, metal tube, rod, nut, and dustproof as well.
 
Features:                                                                                                  
a) Material: Vinyl/Soft PVC
b) Flexible & Durable - Won't Split, Tear or Shred
c) Dust Proof, Fire Resistant, UV Resistant,Environmentally Friendly
d) Printable Surface for private labelling
e) Certificate: REACH, RoHS, UL
 
Property:                                                                                        
 
  Item                                                                                          Test Standard                                                      Test Method                               Result
Appearance                                                                      Clean, Smooth, Transparent, No Bubble                            Visual Inspection                               PASS

Aging Test                                                            168Hrs@136°C without aging                                Aging Box                               PASS
Insulation Resistance                                               DC 500V, Insulation Resistance R≥200MΩ             Insulation Tesistance Tester             PASS
Dielectric Withstand Voltage Test                            AC 2500V/Min (5mA)  No  Breakdown                   Dielectric Withstand Voltage Tester     PASS
Corrosion Resistance                                                Company standard: Q/HT-2004                               Corrosion Device                            PASS
Flammability                                                                            Standard UL 94 V-0                                            Flame Burning                         PASS
      
Internal poly bag and external carton. Special packaging could be customized.

Shipping:

wire harness use heat shrink end caps heat shrink end cap 200mm                                                                                                 
            
Any shipping method is available including courier & forwarder.

Harnessing End Caps

Heat Shrink Wire Caps,Heat Shrink Caps,Elastic Sealing Cap,Heat Shrink End Caps

KEYUACE Materials Co., Ltd. , https://www.insulationtubing.com