YAG50 marking machine common faults and treatment methods

First, no light

1. On the old Q drive, ON, OFF, and RUN are the three-gear selection errors. OFF is the forced turn-off of the laser command and ON is the mandatory light command. The correct method is to select the RUN operation.

2, bad card, replace the card. The Q signal voltage on the board, under normal circumstances, the Q signal voltage is: low level when Kairui board, that is 0V when marking, +5V when not marking; gold orange board card marking High level, which is 5V when marking, 0V when not marking.

3, the signal connection between the board and the driver is open, replace or re-welding.

4, the light path is not adjusted, re-adjust the light path.

5, bad light, replace the light.

6, computer operating system or computer failure, reinstall the system or replace the computer.

7, bad laser power, replace the laser power supply.

8. The Q driver is bad and replace the Q driver.

9, Q switch is bad, replace Q switch.

Second, weak light

1. The marking software CW mode is not selected and the light will be very weak. Select CW mode.

2. The wrong position of M1, M2, and M3 on the Q driver is selected. The correct way is to select M1.

3, the focal length is wrong, refocusing.

4, the water temperature is too high.

5, xenon lamp aging, replacement xenon lamp.

6, all-trans or semi-reflective lenses, focusing lenses, oscillating lenses, Q switch lens dirty or rub flowers. Wipe clean or replace.

7. The cavity, total reflection mirror, half mirror and beam expander are not adjusted and readjusted.

8, Q switch is not adjusted well, the normal situation is marking light, do not mark the Q switch to lock the laser. The current of the laser power supply can be properly adjusted and the frequency doubler is placed in front of the half mirror to see if there is any light leakage. If light leaks, the light will be weak and the Q switch will be readjusted.

9, the laser did not hit the galvanometer center, or galvanometer lens scratches. Re-adjust the light path or replace the galvo mirror.

Third, continuous light

1, the wrong switch sequence may cause continuous light. The correct power-on sequence is: Total Power => Computer => Marking Software => Chiller => Q Drive => Laser Power => Equalize Power READY light on => Press RUN key to start => Power switch . The order of shutdown is the opposite.

2. The ON, OFF, RUN gear switch on the old Q driver is wrongly selected, ON is the forced light command, and OFF is the forced turn off of the laser command. The correct method is to select RUN.

3, bad card, replace the card. Kairui board should also pay attention to the jumper cap above the board: YAG50 jumper cap should jump T end. (Be sure to pay attention to this issue when replacing the Kai Rui board)

4, Q switch is not adjusted well, the normal situation is when the marking light, do not mark the Q switch to lock the laser.

6, if Kai Rui software may also be due to marking software problems, reinstall.

7, computer or operating system problems. Replace or reinstall the system.

8. The Q driver is bad and replace the Q driver.

9, Q switch is bad, replace the Q switch (this situation is less, in general Q switch is broken, Q drive will alarm)

Fourth, galvanometer does not move

1. The X, Y ratio adjustment option on the Kairui software is zero, and the galvo will not move and adjust the parameters.

2, bad card, replace the card. The voltage of X and Y galvanometer signals on the card is normally 0-5V during marking and 0V when not marking.

3, galvanometer signal line open, replace.

4, Qinlong's galvanometer, the driver on the jumper cap next to the signal indicator must be removed, or galvanometer will not move.

5, galvanometer failure, replace the galvanometer.

6, computer operating system or computer failure, reinstall the system or replace the computer.

Five, galvanometer jitter and howling

1, the ground is not connected, re-connect the ground.

2, bad card, replace the card.

3, turn off the laser power supply, Q drive, hand gently touch the galvanometer lens jitter or whether the whistle whistle, if troubleshooting, then turn on the laser power and Q drive one by one to determine whether the laser power or Q drive caused .

4, if it is because of the laser power supply caused by galvanometer jitter or howling, the laser power supply high-voltage line and other signal lines as much as possible, in general, can be troubleshooting. If the fault persists, replace the laser power supply.

5. If it is because the Q driver causes the galvanometer to shake or whistle, you should check whether the connection between the Q driver and the Q switch is short circuited. Short circuit of the signal line will cause this failure. If the fault persists, replace the Q drive.

6, galvanometer bad, replace the galvanometer.

7, computer operating system or computer failure, reinstall the system or replace the computer.

Six, Kai Rui marking software will automatically turn off after opening (YMDF, RF series marking machine processing method is consistent,)

1, dongle is not installed, reinstall.

2. The driver of the dongle is not installed. Reinstall the driver.

7. Marking effect is not good (YMDF, RF series marking machine processing method is the same)

1. The reason for marking the software or system. Reinstall the system or marking software.

2. The parameters of the marking software are not adjusted and the parameters are adjusted again.

3, the focal length is not adjusted, re-adjust the focal length.

4, marking the graphics did not do a good job or marking materials not.

Eight, graphics deformation (YMDF, RF series marking machine processing methods are the same)

1, the graphics itself is not done, redo.

2, the parameters are not adjusted, re-adjust the distortion correction inside the pillow-shaped drum and horizontal vertical correction.

3, galvanometer did not adjust well. readjust.

4, Marking software or system problems, re-install marking software or system.

5, bad galvanometer, replace the galvanometer.

Nine, the wrong size (YMDF, RF series marking machine processing method is the same)

1, the size of the exported graphics itself does not match the size of the required graphics, re-map. Simple graphics can be changed with marking software, and complex graphics are easily deformed.

2. The focal length has changed and the focal length is readjusted.

3. The proportion parameter is not adjusted well. Readjust the parameters.

4. If multiple patterns are marked in the same figure, the size of each pattern is different. Gold Orange Software can adjust the correction parameters. Kairui software does not have this parameter to adjust.

X. Marking misplacement after working for a period of time (YMDF and RF series marking machine processing methods are the same)

1. The screws holding the galvanometer are not locked and the galvanometer is fixed tightly.

2. Operating system or marking software problems, or operating system with anti-virus software can sometimes cause this problem. Reinstall the system or remove the antivirus software and reinstall the marking software.

3, the problem of the galvanometer itself, replace the galvanometer.

Eleven, marking a straight wave (YMDF, RF series marking machine processing method is the same)

1, the ground is not not connected, re-grounding line.

2, galvanometer problem, replacement galvanometer,

3, laser power, static electricity and other interference.

Twelve, foot switch does not work (YMDF, RF series marking machine processing methods are the same)

1. The foot switch must be marked with a small triangle on the toolbar of the marking software (press F5 to pop up the marking dialog box). If you click on the Mark button in the status bar to mark, the foot will jump. The switch will not work.

2, bad foot switch, replace the foot switch.

3, bad board. Footswitch signal voltage, normal condition is that there is a 5V signal voltage for both marking and non-marking.

4. The signal connection between the board and the foot switch is open.

5. If it is a gold orange board, check whether the setting of (F3 parameter)/port/start mark port/input port is 0. If it is not set to 0, the foot switch will not work.

XIII. Air switch tripping

1. Check if there is high pressure ignition

2. Check if the output power exceeds the rated power

3, the main circuit components are damaged

14. The chiller does not work

1. The chiller power cord is connected

2. Check if the input voltage is low

3. Chiller malfunction

Twist Locking Pipe

Unique 2D barcodes are encapsulated at the bottom of each bar code Twist Locking Elbow, allowing Twist Locking Parts to safely identify and track samples even under harsh laboratory conditions. Decode the 2D barcode of each tube when using Thermo Scientific; Scan the Twist Locking System into an application or database, or consolidate it through multiple data export options -- your choice. Once the sample data is stored, just use the database search function to scan the Twist Locking Pipe, and you can immediately access the sample information of each storage tube and identify its content.