Sv20 Pilot Operated Check Valve

Model NO.: SV20PA1-40
Pressure: High Pressure
Valve Structure: Pilot Piston Structure
Power Supply: DC Solenoid Valve
Usage: Emptying
Standard: DIN
Application: Industrial Usage, Water Industrial Usage, Household Usage
Nodular Cast Iron: Qt500
Trademark: Power or OEM
Transport Package: Carton
Specification: ISO9001
Origin: China
HS Code: 8481201000
Model NO.: SV20PA1-40
Pressure: High Pressure
Valve Structure: Pilot Piston Structure
Power Supply: DC Solenoid Valve
Usage: Emptying
Standard: DIN
Application: Industrial Usage, Water Industrial Usage, Household Usage
Nodular Cast Iron: Qt500
Trademark: Power or OEM
Transport Package: Carton
Specification: ISO9001
Origin: China
HS Code: 8481201000
- For sub-plate mounting,
   porting pattern to DIN 24 340 Form A,
   ISO 5781 and CETOP-RP 121 H,
- For threaded connection
- With or without drain port
- With or without unloading function
- 4 cracking pressures
 
SV and SL valves are hydraulic pilot operated check valves in poppet type design which may be 
opened to permit reverse flow.
These valves are used for the isolation of operating circuits under pressure, to prevent a load from falling or  creeping movements of hydraulically locked-in actuators.
Basically these valves consist of housing (1), poppet (2),compression spring (3), control spool (4) as well as a optional pre-opening ball poppet valve (5).
Type SV (without drain port)The valve enables free flow from A to B, in the 
counter direction the poppet (2) is held on its seat by the system pressure, additionally to the spring 
force. Through the pressure connection at control port X the control piston (4) is moved to the right. 
This pushes the poppet (2) from the seat, then fluid flows from B to A.
Function and configuration
In order to ensure the proper opening of the valve via the control piston (4) a certain minimum control pressure is necessary.
Type SV...A...and SL...A... (with pre-opening)   
This valve has a additional pre-opening see hereinafter left configuration. Through pressure 
connection at control port X the control piston (4) is pushed to the right. The ball poppet(5.1) leaves 
first  then the poppet (2) leaves from the seat. 
Now the valve may also have a flow from B to A.
Because of the pre-opening there is a dampened decompression of the fluid under pressure to 
avoid possible pressure shocks.
Type SL... (with drain port )
The function of this valve is principally the same as the valve SV  hereinafter right configuration.
The difference is the additional leakage port Y. 
The annulus area of the control piston (4) is separated from port A. The pressure at port A only 
effects area A4 (9) of the control piston (4).
Sv20 Pilot Operated Check ValveSv20 Pilot Operated Check ValveSv20 Pilot Operated Check ValveSv20 Pilot Operated Check ValveSv20 Pilot Operated Check ValveSv20 Pilot Operated Check Valve
- For sub-plate mounting,
   porting pattern to DIN 24 340 Form A,
   ISO 5781 and CETOP-RP 121 H,
- For threaded connection
- With or without drain port
- With or without unloading function
- 4 cracking pressures
 
SV and SL valves are hydraulic pilot operated check valves in poppet type design which may be 
opened to permit reverse flow.
These valves are used for the isolation of operating circuits under pressure, to prevent a load from falling or  creeping movements of hydraulically locked-in actuators.
Basically these valves consist of housing (1), poppet (2),compression spring (3), control spool (4) as well as a optional pre-opening ball poppet valve (5).
Type SV (without drain port)The valve enables free flow from A to B, in the 
counter direction the poppet (2) is held on its seat by the system pressure, additionally to the spring 
force. Through the pressure connection at control port X the control piston (4) is moved to the right. 
This pushes the poppet (2) from the seat, then fluid flows from B to A.
Function and configuration
In order to ensure the proper opening of the valve via the control piston (4) a certain minimum control pressure is necessary.
Type SV...A...and SL...A... (with pre-opening)   
This valve has a additional pre-opening see hereinafter left configuration. Through pressure 
connection at control port X the control piston (4) is pushed to the right. The ball poppet(5.1) leaves 
first  then the poppet (2) leaves from the seat. 
Now the valve may also have a flow from B to A.
Because of the pre-opening there is a dampened decompression of the fluid under pressure to 
avoid possible pressure shocks.
Type SL... (with drain port )
The function of this valve is principally the same as the valve SV  hereinafter right configuration.
The difference is the additional leakage port Y. 
The annulus area of the control piston (4) is separated from port A. The pressure at port A only 
effects area A4 (9) of the control piston (4).
Sv20 Pilot Operated Check ValveSv20 Pilot Operated Check ValveSv20 Pilot Operated Check ValveSv20 Pilot Operated Check ValveSv20 Pilot Operated Check ValveSv20 Pilot Operated Check Valve

USB short for Universal Serial Bus, is an industry standard developed in the mid-1990s that defines the cables, connectors and communications protocols used in a bus for connection, communication, and power supply between computers and electronic devices.

It was designed to standardize the connection of computer peripherals (including keyboards, pointing devices, digital cameras, printers, portable media players, disk drives and network adapters) to personal computers, both to communicate and to supply electric power. It has become commonplace on other devices, such as smartphones, PDAs and video game consoles.


usb connector

USB Cable and Adapter

Cellphone Charging Data Cable, USB Cable And Adapter, Micro USB Cable, USB Data Cable

Ningbo Kabling Enterprise Limited , http://www.kablinglancable.com